AVA5-50 HELIAX® Andrew Virtual Air™ Coaxial Cable
Introduction
The AVA5-50 HELIAX® Andrew Virtual Air™ is an advanced, high-quality coaxial cable developed by CommScope. Designed for wireless applications, this cable provides high flexibility, reliability, and electrical efficiency, making it the ideal choice for your telecommunications projects. With a 100% corrugated copper shield and black PE jacket, this cable is perfect for a wide range of environmental conditions, ensuring optimal and long-lasting performance.
******Price per meter******
Technical Specifications
Product Classification
- Product Type: Wireless Coaxial Cable
- Product Brand: HELIAX®
- Product Series: AVA5-50
- Ordering Note: CommScope Standard Product [Global]
General Specifications
- Flexibility: Standard
- Jacket Color: Black
Dimensions
- Diameter over Dielectric: 24.13 mm (0.95 in)
- Diameter over Jacket: 27.991 mm (1.102 in)
- Inner Conductor Diameter: 9.449 mm (0.372 in)
- Outer Conductor Diameter: 25.4 mm (1 in)
- Nominal Size: 7/8 in
Electrical Specifications
- Cable Impedance: 50 ohm ±1 ohm
- Capacitance: 73 pF/m (22.25 pF/ft)
- DC Resistance, Inner Conductor: 1.435 ohms/km (0.437 ohms/kft)
- DC Resistance, Outer Conductor: 1.116 ohms/km (0.34 ohms/kft)
- DC Test Voltage: 6000 V
- Inductance: 0.184 µH/m (0.056 µH/ft)
- Insulation Resistance: 100000 MOhms-km
- Jacket Spark Test Voltage [rms]: 8000 V
- Operating Frequency Band: 1 – 5000 MHz
- Peak Power: 91 kW
- Velocity of Propagation: 91 %
- VSWR / Return Loss (dB):
- 680–800 MHz: 1.13 / 24.3 dB
- 800–960 MHz: 1.13 / 24.3 dB
- 1700–2200 MHz: 1.13 / 24.3 dB
Attenuation
- Frequency [MHz]: Attenuation [dB/100 m] | Attenuation [dB/100 ft] | Average Power [kW]
- 1.0: 0.113 | 0.034 | 74.43
- 2.0: 0.16 | 0.049 | 52.56
- 10.0: 0.359 | 0.11 | 23.37
- 50.0: 0.814 | 0.248 | 10.32
- 100.0: 1.162 | 0.354 | 7.23
- 200.0: 1.665 | 0.507 | 5.05
- 400.0: 2.398 | 0.731 | 3.5
- 800.0: 3.478 | 1.06 | 2.42
- 1000.0: 3.927 | 1.197 | 2.14
- 2000.0: 5.771 | 1.759 | 1.46
- 3000.0: 7.272 | 2.217 | 1.15
- 5000.0: 9.806 | 2.989 | 0.86